- 1
- M. Anliker and R. Rockwell.
Nonlinear analysis of flow pulses and shock waves in arteries.
ZAMP, 22:217-246, 1971.
- 2
- A. C. L. Barnard, W. A. Hunt, W. P. Timlake, and E.
Varley.
A theory of fluid flow in compliant tubes.
Biophys. J., 6:717-724, 1966.
- 3
- S. Canic.
The influence of self-expanding stents on the blood flow after
endovascular repair.
In preparation.
- 4
- S. Canic.
Blood flow through compliant vessels after endovascular repair: wall
deformations induced by the discontinuous wall properties.
Comp. Vis. Science. To appear.
- 5
- S. Canic and E. Kim.
Mathematical analysis of the quasilinear effects in a hyperbolic model
of blood flow through compliant axi-symmetric vessels.
Submitted to SIAM Appl. Math.
- 6
- S. Canic and D. Mirkovic.
A hyperbolic system of conservation laws in modeling endovascular
treatment of abdominal aortic aneurysm.
Proc. 8th Int. Conf. Hyperbolic Problems. To appear.
- 7
- L. Formaggia, F. Nobile, and A. Quarteroni.
A one dimensional model for blood flow: application to vascular
prosthesis.
Submitted.
- 8
- L. Formaggia, J.-F. Garbeau, F. Nobile, and A. Quarteroni.
On the coupling of 3D and 1D Navier-Stokes equations
for flow problems in compliant vessels.
Ècole Polytechnique Fèdèrale
de Lausanne Preprint.
- 9
- L. Gosse and F. James.
Numerical approximations of one-dimensional
linear conservation equations with discontinuous
coefficients.
Math. Comp. 69:987-1015, 2000.
- 10
- T. Hou and P. L. Floch.
Why nonconservative schemes converge to wrong solutions: error
analysis.
Math. of Comp., 62:497-530, 1994.
- 11
- J. Keener and J. Sneyd.
Mathematical Physiology.
Interdisciplinary Applied Mathematics. Volume 8, Springer New York,
1998.
- 12
- G. Dal Maso, G.P. Lefloch and F. Murat.
Definition and weak stability of nonconservative products.
J. Math. Pures Appl. (9), 74:483-548, 1995.
- 13
- R. J. LeVeque.
Numerical Methods for Conservation Laws.
Birkhäuser, Boston, 1992.
- 14
- S. T. R. MacSweeney, G. Young, R. M. Greenhalgh, and J. T.
Powel.
Mechanical properties of the aneurysmal aorta.
Br. J. Surg., 79:1281-1284, 1992.
- 15
- M. Olufsen, C. Peskin, W. Kim, E. Pedersen, A. Nadim, and
J.
Larsen.
Numerical simulation and experimental validation of blood flow in
arteries with structured-tree outflow conditions.
Ann. Biomed. Eng., 28:1281-1299, 2000.
- 16
- D. Ostrov.
Solution of Hamilton-Jacobi equations and scalar conservation laws with
discontinuous space-time dependence.
Submitted.
- 17
- D. Ostrov.
Extending viscosity solutions to eikonal equations with discontinuous
spatial dependence.
Nonlin. Anal., 42:709-736, 2000.
- 18
- C. Peskin.
Partial Differential Equations in Biology.
Courant Institute of Math. Sci., Lecture Notes, New York, 1975.
- 19
- T. Umscheid and W. J. Stelter.
Time-related alterations in shape, position, and structure of
self-expanding, modular aortic stent-grafts.
J. Endovasc. Surg., 6:17-32, 1999.
- 20
- R. Wang and K. Ravi-Chandar.
Mechanical response of a metallic aortic stent.
Center for Mechanics of Solids, Structures and Materials, UT Austin,
EMRL Rep. No: 01-01.
- 21
- A. I. Vol'pert.
The spaces BV and quasilinear equations.
Mat. Sbornik 73(115) No.2 (1967).